RX 51x- Combination Gas Detectors
Description
The RX-51X Series includes the RX-515, RX-516, and RX-517
RX-515 Application LNG gas tank vessels
The RX-515 gas detector, which measures CH4, O2, CO and CO2, is characterized by its versatility, as it has an infrared sensor (NDIR), a galvanic sensor and an electrochemical sensor. Despite the large number of sensors, the sensors offer an accurate measurement even in inert atmospheres. The measuring ranges vary from 0-100% LEL / 0-100 vol. % For CH4, 0-25 vol. % For O2, 0-1000 ppm for CO and 0-20 vol. % CO2. Furthermore, the device can safely be used in virtually any environment thanks to its inherent design, without jeopardizing the user.
RX-516 & RX-517- Application Crude oil tankers
The gas detectors RX-516 and RX-517 have a combination of infrared, galvanic and electrochemical sensors. Thanks to the specialized sensors, an accurate measurement of HC, and O2 and H2S concentrations even in inert atmospheres.
The measurement ranges of the RX-516 are 0-100% LEL / 0-100 vol.% For HC, 0-25 vol.% For O2 and 0-100 ppm for H2S. An additional higher resolution for H2S (0-1,000ppm) is offered with the RX-517. A separate flow channel for highly concentrated H2S applications, on which the remaining sensors are protected from harmful concentrations, is specifically cleared with a manual switch. These two devices also have an intrinsically safe design so that they are suitable for almost any
application environment. An additional measurement resolution for H2S (0-1,000ppm) is offered with the RX-517. A separate flow channel for highly concentrated H2S applications, on which the remaining sensors are protected from harmful concentrations, is specifically cleared with a manual switch.
These two devices also have an intrinsically safe design so that they are suitable for almost any application environment. An additional measurement resolution for H2S (0-1,000ppm) is offered with the RX-517. A separate flow channel for highly concentrated H2S applications, on which the remaining sensors are protected from harmful concentrations, is specifically cleared with a manual switch. These two devices also have an intrinsically safe design so that they are suitable for almost any application environment.
Features
Dual range detection of CH4 or HC in %Vol and %LEL
Unique gas combinations include:CH4/O2/CO/CO2/HC/O2/H2S
Measuring CH4 or HC from inerted tanks with IR sensor
High range H2S 0-1000 ppm available (RX-517)
Datalogging standard
ATEX and MED approved (Wheelmark)